TURBO-COOL® Evaporative Cooling System for Broilers

Reinforced, Continuous, One-Piece Trough
  • One-piece trough is made of heavy-duty, ultraviolet-resistant polypropylene and has no problematic joints where leaks and breaks tend to occur in others’ systems.
  • Fabric-reinforced trough material is proven under the harshest conditions and provides self-contained water storage.
  • Unlike competitors’ rigid plastic troughs, Chore-Time’s seamless trough design is easy to install, saving time and expense on your new construction or retrofit project.
feature
Open Top Design
  • Unique, large 2-inch (51-mm) pipe and 5/32-inch (4-mm) water distribution holes.
  • Uniform water distribution up to 75 feet (22.9 m), or 110 feet (33.5 m) with a center-mounted sump.
  • See water jets and check water pressure easily.
  • Easy access to pipe for cleaning.
  • Pipe includes removable end plugs for cleaning.
  • System includes rubber water-containment seals at system ends.
feature
Well-Designed, Innovative Sump Tank
  • Includes reinforcing ribs for greater strength and durability, and a drain plug for seasonal service.
  • Reliable automatic float valve matches water supply to demand and helps maintain consistent pad wetting.
  • Specially engineered to hold submersible pump and low water safety switch. (Switch is included in standard system.)
  • Clever design allows tank to be mounted at either end or in middle of system.
  • Convenient bleed-off valve and easy access shut-off.
feature
Designed for Easy Pad Maintenance
  • Full-width plastic support tray under pads improves pad support and extends pad life.
  • Pads are easy to remove for cleaning without hardware or tools.
  • Trough provides self-contained water storage.
High-Performance Pad
  • Standard 45/15 fluting and 12-inch (30.5-cm) pad width.
  • Pad heights: 2, 3, 4, 5 or 6 feet (0.5, 0.9, 1.2, 1.5 or 1.8 meters).
  • Standard pad includes black protective coating.
  • Protective bottom coating is optional.
feature
Photos & Videos
Photos:
Literature
Manuals
Specifications
White Papers
thumbnail
Cooling Systems, Air Inlets & Winches
(CT-2571-202411)
thumbnail
MV1644X MV1644V TURBO-COOL Closed Top 6-Inch Recirculating Evaporative Cooling Install & Operate
May 2021
thumbnail
MV1669W TURBO-COOL With Open Top 6-Inch Recirculating Evaporative Cooling Install & Operate
May 2021
thumbnail
MV1670R TURBO-COOL Stand-Off With Open Top 6-Inch Recirculating Evaporative Cooling Install & Operate
Jan 2014 – Previous
thumbnail
MV1901B TURBO-COOL 90-Degree Around The Corner Kit (50464) Install & Instruction
Sep 2015